General Information
The TV89 Solenoid Valve is compatible with all TYFON® sound emitters, including types KT 75/– and MKT 75/–. You can mount the valve either indoors or encased outdoors. However, for optimal performance, install the solenoid in an upright and vertical position. Additionally, to achieve distinct code signals, ensure that the pipe length does not exceed 6 meters between the valve and the TYFON.
Installation Guidelines
To maintain effective signal quality, you must insert a choke disc with a reduced orifice either at the valve or before the TYFON. Furthermore, thoroughly blow out the pipeline with compressed air before connecting it to the signaling apparatus. This step ensures the removal of any debris that may obstruct the system.
When placing an order, please specify the valve type, voltage, and working pressure. For additional information, refer to the attached document for a working pressure table, dimensions, and reference numbers. By following these guidelines, you will ensure optimal functionality and reliability of your solenoid valve in various applications.
Contact Us for More Information
If you have any questions or require the TV89 Solenoid Valve of Kockum Sonics.
Technical Data
- Standard voltage: 24V, 115V, 230V DC
115V, 230V AC - Cable gland Pg 11
- Cable diameter 8-10 mm
- Connection screw
terminals max 1,5 mm2
Working pressure: 1,2 – 3,0 MPa (overpressure) - Power consumption: 8W
- Protection class: IP 65
- Ambient temperature: 80°C
- Pipe dimension: 10mm
- Weight of valve with filter: 0,8 kg