Venteville, agent, distributor, service provider of Evoqua
Venteville

Vaartuigen LOA > 200m

Vaartuigen LOA > 200m

Vaartuigen LOA > 200m – Products

MKT 150/110 air whistle, suitable for vessels with a LOA > 200m

 

Regulations Before and After COLREG 1972

Before “COLREG 1972” (International Regulations for Preventing Collisions at Sea), low-pitched tones were often used for smaller vessels. However, the principle of reserving low tones for large vessels was not strictly enforced. The IMO regulations now reserve very low tones exclusively for the largest ships. For middle-sized and smaller vessels, there are broader frequency options available.

 

Signal Preferences and Frequency Range

IMO regulations prioritize signals that maintain audibility even at a distance. Vessels over 200 meters (656 feet) should use whistles with frequencies of 130 Hz or lower. These frequencies ensure effective communication and compliance with maritime safety standards.

 

Installation Instructions for MKT 150/110

Mounting the MKT 150/110

Secure the MKT 150/110 whistle with four M12 bolts to an outrigger or similar construction. Ensure the structure is stable to prevent any operational issues.

 

Cleaning the Supply Pipe
Before connecting the supply pipe to the whistle, blow the pipe thoroughly clean. This step is crucial to avoid any functional troubles caused by debris or contaminants in the pipe.

 

Installing a Primary Filter
If the pipeline above deck exceeds 100 meters (328 feet), install a primary FILTER TP 15/2 at the base of the mast. This filter protects the whistle from water condensate and rust particles, ensuring reliable operation.

 

Maintaining the Filter
Regular maintenance is essential for ensuring optimal performance. To begin with, it is recommended to drain the filter approximately once a month. By doing so, you can effectively prevent blockages while also maintaining the integrity of the signaling system.

 

Valve Unit Specifications

The VALVE UNIT TV 784 is designed for efficient air flow, featuring thermostatic heating, exchangeable choke flanges, and filters. It includes two coils for normal and emergency operation, as well as a lanyard, providing reliable functionality.

 

Contact Us for More Information

If you have any questions or require spare parts for your Kockum Sonics system.

Contact us.

Technical Data

  • Frequency: 110 Hz
  • Sound Pressure Level (1m):
    Total: 149 dB
    1/3 octave IMO limit: 143 dB
  • Air consumption: 60-70 I/s
  • Air supply pressure: 0,6—3 MPa (6—30 bar)
    Please state the working pressure when order.
  • Electric power:
    Thermostat heating: 24 W
    Valve: 27 W
  • Weight: 52 kg
  • For wiring diagram: see Valve Unit TV 784

MKT 150/90 air whistle, suitable for vessels with a LOA > 200m

Regulations Before and After COLREG 1972

Before “COLREG 1972” (International Regulations for Preventing Collisions at Sea), low-pitched tones were often used for smaller vessels. However, the principle of reserving low tones for large vessels was not strictly enforced. The IMO regulations now reserve very low tones exclusively for the largest ships. For middle-sized and smaller vessels, there are broader frequency options available.

 

Signal Preferences and Frequency Range

IMO regulations prioritize signals that maintain audibility even at a distance. Vessels over 200 meters (656 feet) should use whistles with frequencies of 130 Hz or lower. These frequencies ensure effective communication and compliance with maritime safety standards.

 

Installation Instructions for MKT 150/90

Mounting the MKT 150/90

Secure the MKT 150/90 whistle with four M12 bolts to an outrigger or similar construction. Ensure the structure is stable to prevent any operational issues.

 

Cleaning the Supply Pipe
Before connecting the supply pipe to the whistle, blow the pipe thoroughly clean. This step is crucial to avoid any functional troubles caused by debris or contaminants in the pipe.

 

Installing a Primary Filter
If the pipeline above deck exceeds 100 meters (328 feet), install a primary FILTER TP 15/2 at the base of the mast. This filter protects the whistle from water condensate and rust particles, ensuring reliable operation.

 

Maintaining the Filter
Regular maintenance is essential for ensuring optimal performance. To begin with, it is recommended to drain the filter approximately once a month. By doing so, you can effectively prevent blockages while also maintaining the integrity of the signaling system.

 

Valve Unit Specifications

The VALVE UNIT TV 784 is designed for efficient air flow, featuring thermostatic heating, exchangeable choke flanges, and filters. It includes two coils for normal and emergency operation, as well as a lanyard, providing reliable functionality.

 

Contact Us for More Information

If you have any questions or require spare parts for your Kockum Sonics system.

Contact us.

Technical Data

  • Frequency: 90 Hz
  • Sound Pressure Level (1m):
    Total: 149 dB
    1/3 octave IMO limit: 143 dB
  • Air consumption: 60-70 I/s
  • Air supply pressure: 0,6—3 MPa (6—30 bar)
    Please state the working pressure when order.
  • Electric power:
    Thermostat heating: 24 W
    Valve: 27 W
  • Weight: 52 kg
  • For wiring diagram: see Valve Unit TV 784

MTX 150/130 electrically driven piston whistle, suitable for vessels with a LOA >200m.

 

General Information

The ELECTRO–TYFON® MTX 150/130 is an electrically driven piston ship’s whistle. It features minimal moving parts, a “swinging piston,” a cylinder that requires no lubrication, and an oil-free gearbox.

 

Key Features

  • Unsymmetrical Sound Distribution: The design ensures the sound is distributed unevenly for efficient signaling.
  • Adaptability: It operates effectively in all temperatures without additional measures.
  • Stability: The whistle remains unaffected by voltage and frequency fluctuations.
  • Maintenance-Free: The whistle is oil-free, non-corrosive, and requires no maintenance.
  • Easy Installation: Simplified installation process.
  • Compliance: Fully complies with International Regulations IMO 1972.

 

All-Temperature Operation

The ELECTRO–TYFON® MTX 150/130 delivers high performance in both arctic and tropical climates. Its patented system, featuring a high-efficiency rectangular horn and a specially designed motor, automatically adjusts the motor speed to match the horn’s acoustic resonance, regardless of ambient temperature. This ensures the whistle remains unaffected by onboard voltage and frequency fluctuations.

 

Unsymmetrical Sound Distribution

IMO Regulations demand a high Sound Pressure Level for effective signaling, but the sound level at the vessel’s listening posts should not exceed 110 dBA. To solve this, the whistle is typically placed high above the deck. However, if the highest point is insufficient, doubling the distance between the listening post and the whistle can reduce noise by 6 dB.

 

Contact Us for More Information

If you have any questions or require Kockum Sonics ship whistle or spare parts.

Contact us.

 

 

Technical Data:

  • Sound frequency (basic): 130 Hz
  • Sound Pressure Level acc to IMO (1/3 oct band): >143 dB/1m
  • Sound Level A-weighted: 146 dBA/1m
  • Electrical protection class: IP 56
  • Colors:
    Body Galvanized nat.
    Motor Grey RAL 7030
    Horn White RAL 9003
  • Weight (approx.): 70 kg

 

COMMON SPARE PARTS AVAILABLE FROM STOCK:

 

Manufacture PN

Description

Remark

20750100 Connection box
20862066 O-ring
20862066 O-ring 57,6 x 2,4
20880002 Bearing for Crankshaft
20880003 Bearing rear
20880005 Bearing front
21750123 Horn
21765049 Packing
21768357 Gear wheel 50Hz
21768358 Motor gear wheel 50Hz
21768359 Gear wheel 60Hz
21768360 Motor gear wheel 60Hz
21768368 Flange
21768373 Spacer
21768376 Spacer
21768399 Cap
21768404 Spacer
21768473 Mounting flange
21768545 Crankshaft Gear Wheel 60 Hz
21768984 Outlet
21768986 Cylinder
21769059 Cover
21769060 Fixing screw
21769060 Screw
21769402 Cylinder
21800420 Motor set 380-440V/50-60Hz
21801030 Motor set 660-690V/50-60Hz
24530267 Motor Gear Wheel 50 Hz
24530268 Motor Gear Wheel 60 Hz
24530291 Piston rod set
24530292 Crank shaft set
24530292 Crankshaft Set
24530293 Vibration damper set
24530294 Clamp set
24530296 Piston set
24530297 Mounting details
24800585 Crank shaft set
24800703 Motor set 380-440V/50-60Hz
24800704 Motor set 660-690V/50-60Hz
32470024 Circlip
32470028 Circlip
34240705 Bearing (2 in set) for motor
20611031 Motor set 440V/60Hz Obsolete

 

 

Send your inquiry to info@venteville.com

General Information

To ensure safety, the TK80 contactor unit includes a thermal overload relay that protects the installation from excessive current. This relay has a set point of 13A, providing reliable protection during operation. By default, the relay operates with an automatic reset feature (A), which simplifies management for users. However, operators can change the relay function to a manual reset option (H). In this case, the user must reset the overprotection using the green pushbutton, adding an extra layer of control.
 

Additional Features

Moreover, the unit supplies heating voltage to the ELECTRO-TYFON®. This heating voltage automatically switches off during signaling, optimizing energy efficiency and enhancing safety. As a result, operators can count on the system for consistent performance and protection under various conditions. Overall, these features make the contactor unit a vital component in ensuring reliable and safe operation.
 

Contact Us for More Information

If you have any questions or require the TK80 of Kockum Sonics.

Contact us.

Technical Data

  • Main voltage:  max 690V AC
  • Control voltage:  230V AC, 50/60Hz (other voltages optional)
  • Heating:  30 – 55 V AC, max 100 VA
  • Operating ambient temperature: 0…+50 °C
  • Protection class: IP54

Dimensions

  • W x H x D: 300 x 300 x 155 mm
  • Mounting holes: 4 x Ø8.5 mm
  • Distance between mounting holes: 260x260mm
  • Cable glands: 2 pcs M32 for cable Ø 19 – 31 1 pc M25 for cable Ø 11 – 20
  • Connection plinths: Cables Ø 0,52-6mm.
  • Colour: RAL 7035
  • Weight: 7.9 kg
Venteville